Free tool: See what pool pros charge in your area → poolrates.fyi
Hayward

EcoStar Discontinued

Variable Speed Pump

The Hayward EcoStar was one of Hayward's flagship variable speed pumps. While now discontinued and replaced by newer VS models, the EcoStar remains widely installed and commonly serviced in the field.

Hayward EcoStar Variable Speed Pump
240 VAC
Voltage
3450 RPM
Max Speed

Specifications

Motor
TypeTEFC
TechnologyPermanent Magnet
Electrical
Voltage240 VAC
Performance
Max Speed3450 RPM

Pros & Cons

Pros

  • 8 programmable speed settings with countdown timers
  • Compatible with Hayward OmniLogic and ProLogic automation
  • Quiet operation at low speeds

Cons

  • Discontinued — replacement parts becoming harder to source
  • No flow sensing (speed-based only)

Error Codes & Troubleshooting

Check System - AC Mains Low
Input voltage below acceptable range
Troubleshoot this →
Check System - Overheated
Drive or motor thermal protection tripped
Troubleshoot this →
Check System - Overloaded
Motor drawing excessive current
Troubleshoot this →
Check System - Pump Stalled
Motor unable to rotate (impeller jam or seized bearing)
Troubleshoot this →
Communication Failed
Loss of communication with automation system
Troubleshoot this →

Open full interactive troubleshooter →

Replacement Parts

PartPart NumberDescription
Drive AssemblySPX3400DRStandard drive assembly
Drive Assembly (SVRS)SPX3400DRVRSVRS drive assembly
Display AssemblySPX3400LCDDigital control interface
Blank CoverSPX3400DR9Cover for wall mount
Wall Mount PlateSPX3400DR10Wall mount plate

Related Models

Related Articles

Track This Equipment on Customer Accounts

Log equipment details, service history, and warranty info for every customer with PoolDial.

Start Free Trial